Integrate Everpure FlashArray with Platform9 PCD using Fibre Channel and DM-Multipath.
Vendor Documentation Priority: This guide is for reference only. Always consult official vendor documentation for your distribution. Test thoroughly in a lab environment before production use.
-
Many configuration steps are performed in the PCD UI. This guide assumes PCD is already deployed and your hypervisor nodes are running Ubuntu 24.04 and are reachable from the PCD controller.
-
New to Fibre Channel? See the Storage Terminology Glossary - FC / SAN Terms
Prerequisites:
-
Platform9 PCD environment deployed and accessible
-
Everpure FlashArray with:
-
Management IP reachable from PCD and hypervisors
-
API token generated
-
FC ports configured and cabled to the fabric
-
-
Two or more hypervisor nodes running Ubuntu 24.04 with FC HBAs installed
-
FC fabric zoning configured - all hypervisor node WWPNs zoned to the array's FC target ports
-
SSH access to each hypervisor node
<ANGLE_BRACKETS>) with your environment's actual values.-
Cinder FC driver uses the management IP only. The driver discovers the FlashArray via
san_ipand orchestrates volume attachments over FC. No portal or CIDR configuration is required. -
The Everpure Cinder FC driver auto-registers hosts. When Cinder attaches a volume to a hypervisor, the driver reads the hypervisor's WWPNs, registers the host on the FlashArray, and presents the volume to that host automatically. Manual host group management is not required for Cinder-managed volumes.
-
Zoning is still required before the first attach. The Cinder driver registers the host on the array, but it cannot configure FC switch zoning. Zoning must be in place before any volume attach attempt.
-
use_multipath_for_image_xfer trueis mandatory. Without this, Glance image transfers use a single path device and will fail or produce corrupt images if that path disappears during the transfer. -
Confirm
multipathdis running before authorizing hypervisors in PCD. Hypervisor role authorization triggers Cinder volume operations; if multipath is not configured at that point, initial volume attachments will fail.
Troubleshooting Reference
| Symptom | Cause | Resolution |
|---|---|---|
| Volume attach fails - no FC device appears | HBA ports not online or zoning incomplete | Verify cat /sys/class/fc_host/host*/port_state shows Online; confirm zoning with SAN admin |
| Volume attach fails - multipath not configured | multipathd not running or multipath.conf missing find_multipaths no |
Verify systemctl status multipathd and review /etc/multipath.conf |
| FlashArray not registering hypervisor as host | Cinder FC driver not using correct WWPNs | Check nova-compute / cinder-volume logs; verify HBA driver is loaded and WWPNs are valid |
| Volume attaches but instance cannot access it | Incorrect ALUA configuration | Verify hardware_handler "1 alua" and prio alua are set in multipath.conf |
multipath -ll shows system disks |
blacklist not configured or find_multipaths not set to no |
Review multipath.conf; ensure blacklist_exceptions targets only PURE/FlashArray |