Integrate Everpure FlashArray with Platform9 PCD using iSCSI and DM-Multipath
Vendor Documentation Priority: This guide is for reference only. Always consult official vendor documentation for your distribution and storage array. Test thoroughly in a lab environment before production use.
-
Many configuration steps are performed in the PCD UI. This guide assumes PCD is already deployed and your hypervisor nodes are running Ubuntu 24.04 and are reachable from the PCD controller.
-
New to iSCSI? See the Storage Terminology Glossary - iSCSI Terms
Pre-requisites:
-
Platform9 PCD environment deployed and accessible
-
Everpure FlashArray with:
-
Management IP reachable from PCD and hypervisors
-
API token generated
-
iSCSI ports configured
-
-
Two or more hypervisor nodes running Ubuntu 24.04
-
Network connectivity between hypervisors and FlashArray iSCSI ports
-
SSH access to each hypervisor node
<ANGLE_BRACKETS>) with your environment's actual values.Troubleshooting Reference:
| Symptom | Troubleshooting |
|---|---|
|
No multipath devices visible (`multipath -ll` shows nothing) |
This is expected when no FlashArray volumes are attached. Attach a volume via PCD, then recheck. |
|
|
Verify |
|
Only one iSCSI path visible |
Verify that the hypervisor has network access to all configured iSCSI ports on the FlashArray. |
|
Paths show as |
Check physical network connectivity and FlashArray port status. |
|
Volume type |
|
Architecture Summary:
PCD Controller
|
v
Cluster Blueprint --> pure-flasharray backend (Pure Storage ISCSI driver)
|
v
pcd-pure-cluster
+-- pcd-hypervisor-01 (Hypervisor + Persistent Storage + Image Library)
| +-- /etc/multipath.conf -> /dev/mapper/mpatha --> FlashArray vol
+-- pcd-hypervisor-02 (Hypervisor + Persistent Storage)
+-- /etc/multipath.conf -> /dev/mapper/mpatha --> FlashArray vol
|
Everpure FlashArray
iSCSI (multi-path, ALUA)
Additional References: