Platform9 Private Cloud Director with Everpure FlashArray

Platform9

Audience
Public
Source Type
Documentation

Provision Platform9 Private Cloud Director (PCD) VM boot and data volumes directly on Everpure FlashArray over iSCSI or Fibre Channel, using the Everpure Cinder driver in the cluster blueprint and DM-Multipath on every Ubuntu 24.04 hypervisor. Covers backend configuration, host multipath setup, and end-to-end verification from the PCD UI down to the array.

Who This Is For

Persona When to use this guide

PCD cloud administrator

You are building a PCD cluster blueprint, adding FlashArray as a persistent storage backend, and authorizing hypervisors with the right roles.

Linux / hypervisor administrator

You own the Ubuntu 24.04 hosts and need to install and tune DM-Multipath (and for FC, verify HBAs and collect WWPNs) so PCD can attach volumes.

Storage administrator

You provide the FlashArray management IP, API token, and iSCSI ports or FC zoning, and want to confirm that PCD-created hosts and volumes appear correctly on the array.

Introduction

  • Stand up FlashArray as a PCD volume backend over iSCSI or Fibre Channel, and boot VMs from FlashArray volumes without hand-creating hosts or volumes on the array.

  • Configure every hypervisor with a FlashArray-specific multipath.conf so each volume attaches with all paths active and ALUA-aware failover.

  • Confirm the integration end to end with iscsiadm, multipath -ll, and lsscsi output, annotated with what healthy paths look like (prio=50 vs prio=10).

Before You Begin

Requirement Where to get it
A deployed PCD environment, with admin access to the PCD UI Platform9 PCD deployment; see the Platform9 PCD documentation
Two or more hypervisor nodes running Ubuntu 24.04, reachable from the PCD controller, with SSH and sudo access Your Linux platform team
FlashArray management IP reachable from PCD and every hypervisor FlashArray network configuration
A FlashArray API token for the Cinder driver FlashArray GUI, or pureadmin create --api-token on the FlashArray CLI
iSCSI: FlashArray iSCSI ports configured and reachable from every hypervisor's storage interface FlashArray network configuration and your network team
Fibre Channel: FC HBAs installed in every hypervisor, cabled to both fabrics, and all hypervisor WWPNs zoned to the FlashArray FC target ports Your SAN administrator (the FC guide shows how to collect the WWPNs)