Network Service Configuration
Before changing the network service to NVMe-TCP, please remember to remove iSCSI network portals while initiators are still connected.
We only allow changing the network service on ETH2 between iSCSI and NVMe-TCP.
$ purenetwork eth setattr --servicelist nvme-tcp ct0.eth2 ct1.eth2
Name Enabled Type Subnet Address Mask Gateway MTU MAC Speed Services Subinterfaces
ct0.eth2 True physical - 172.16.9.48 255.255.255.128 172.16.9.1 1500 6e:05:91:b6:80:e5 16.00 Gb/s nvme-tcp -
ct1.eth2 True physical - 172.16.9.62 255.255.255.128 172.16.9.1 1500 22:eb:6f:e1:06:99 16.00 Gb/s nvme-tcp -
Array Host and Volume Configuration
Array host and volume configuration follows the same procedure as the FlashArray. Please reference Connecting an NVMe-oF Initiator to a Volume.
Array Scale Limit
| Description | Limit |
|---|---|
| Max # of hosts | 300 |
| Max # of volumes | 800 |